SLVSDX8B March 2017 – December 2018 DRV8702D-Q1 , DRV8703D-Q1
PRODUCTION DATA.
Refer to the PDF data sheet for device specific package drawings
FAULT status is shown in Figure 47 and described in Table 15.
Return to Summary Table.
Read only
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
FAULT | WDFLT | GDF | OCP | VM_UVFL | VCP_UVFL | OTSD | OTW |
R-0b | R-0b | R-0b | R-0b | R-0b | R-0b | R-0b | R-0b |
Bit | Field | Type | Default | Description |
---|---|---|---|---|
7 | FAULT | R | 0b |
Logic OR of the FAULT status register excluding the OTW bit |
6 | WDFLT | R | 0b |
Watchdog time-out fault |
5 | GDF | R | 0b |
Indicates gate drive fault condition |
4 | OCP | R | 0b |
Indicates VDS monitor overcurrent fault condition |
3 | VM_UVFL | R | 0b |
Indicates VM undervoltage lockout fault condition |
2 | VCP_UVFL | R | 0b |
Indicates charge-pump undervoltage fault condition |
1 | OTSD | R | 0b |
Indicates overtemperature shutdown |
0 | OTW | R | 0b |
Indicates overtemperature warning |