SLVSGF5A May   2023  – December 2023 DRV8845

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Device Comparison
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Typical Operating Characteristics
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Motor Configurations
      2. 7.3.2 Stepper Control Logic
      3. 7.3.3 DC Motor Control
      4. 7.3.4 PWM Current Control
      5. 7.3.5 Current Regulation and Decay Mode
      6. 7.3.6 Blanking Time
      7. 7.3.7 Charge Pump
      8. 7.3.8 Logic-Level Pin Diagram
      9. 7.3.9 Protection Circuits
        1. 7.3.9.1 VM Undervoltage Lockout (UVLO)
        2. 7.3.9.2 VCP Undervoltage Lockout (CPUV)
        3. 7.3.9.3 Overcurrent Protection (OCP)
        4. 7.3.9.4 Thermal Shutdown (OTSD)
        5. 7.3.9.5 Fault Condition Summary
    4. 7.4 Device Functional Modes
      1. 7.4.1 Sleep Mode (nSLEEP = 0)
      2. 7.4.2 Operating Mode (nSLEEP = 1)
      3. 7.4.3 nSLEEP Reset Pulse
      4. 7.4.4 Functional Modes Summary
  9. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Application Schematics
    3. 8.3 Application Curves
  10. Layout
    1. 9.1 Layout Guidelines
    2. 9.2 Bulk Capacitance
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Charge Pump

A charge pump is integrated to supply a high-side N-channel MOSFET gate-drive voltage. The charge pump requires a capacitor between the VM and VCP pins to act as the storage capacitor. Additionally a ceramic capacitor is required between the CP1 and CP2 pins to act as the flying capacitor.

GUID-20230127-SS0I-GPPL-QJTF-MLVSMK9WMGNQ-low.svgFigure 7-7 Charge pump