SLVSE65C July 2018 – December 2023 DRV8847
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
If the voltage drop at negative terminal of OL2_LS comparator is lower than 1.2-V (VOL_LS), the comparator sets output to "1" showing as open load. Hence, the voltage required to trip the OL2_LS comparator is calculated as:
By putting Equation 26 to Equation 30,
By solving Equation 31, the load resistance (RL) is expressed as,
By putting the values of VAVDD and VOL_LS in Equation 32, the load resistance (RL) is calculated as 25.5-kΩ. Therefore, the output of OL2_HS comparator sets to 1, if the load resistance is greater than 25.5-kΩ.
Since, the OL1_HS comparator always outputs "1", therefore, the open load status is solely dependent on the output of OL2_HS comparator. If OL2_HS comparator output is "1", then an open load is detected.