SLVSE65C July 2018 – December 2023 DRV8847
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
If a resistive load (RL) is connected between OUT1 and GND, then current flowing from AVDD depends on load reistance (RL) as:
Now, if the voltage drop at positive terminal of OL1_HS comparator is higher than 2.3-V (VOL_HS), the comparator sets output to "1" showing as open load. Hence, the voltage required to trip the OL1_HS comparator is calculated as:
By putting Equation 10 to Equation 11,
By solving Equation 12, the load resistance (RL) is expressed as,
By putting the values of VAVDD and VOL_HS in Equation 13, the load resistance (RL) is calculated as 14.52-kΩ. Hence, any resisitive load connected between OUTx and GND above this value is shown as an open-load.
The values of these parameters are taken for a typical case for understanding. These parameters changes with supply voltage and temperature. User has to consider a design margin based on the above calculations.