SLVSFE6A August 2019 – April 2021 DRV8876N
PRODUCTION DATA
If at any time the charge pump voltage on the VCP pin falls below the undervoltage lockout threshold voltage (VCPUV), all MOSFETs in the H-bridge will be disabled and the nFAULT pin driven low. Normal operation will resume when the undervoltage condition is removed and VCP rises above the VCPUV threshold.