SLVSD19A June 2015 – July 2015 DRV8881
PRODUCTION DATA.
To configure the DRV8881 into this mode, pull DECAY1 and DECAY0 logic high.
During fast decay, the polarity of the H-bridge is reversed. The H-bridge will be turned off as current approaches zero in order to prevent current flow in the reverse direction.
Fast decay exhibits the highest current ripple of the decay modes for a given tOFF. Transition time on decreasing current is much faster than slow decay since the current is allowed to decrease much faster.