SLVSDO1C January 2017 – March 2020 DRV8886AT
PRODUCTION DATA.
To observe how VRREF, ARREF, and RREFVRREF affect the IFS error , Equation 3 and Equation 4 are used with the data sheet values from earlier while VDAC voltage remains constant. Table 8, Table 9, and Table 10 list the results at different current levels (1 A, 400 mA, and 200 mA, respectively).
Parameter | Minimum | Typical | Maximum |
---|---|---|---|
VDAC | 0.4107 | 0.4107 | 0.4107 |
ARREF | 28100 | 30000 | 31900 |
VRREF | 1.18 | 1.232 | 1.28 |
RREF | 19800 | 20000 | 20200 |
IFS (mA) | 906.95 | 1000 | 1094.21 |
Error (%) | –9.30 | 9.42 |
Parameter | Minimum | Typical | Maximum |
---|---|---|---|
VDAC | 0.9035 | 0.9035 | 0.9035 |
ARREF | 28100 | 30000 | 31900 |
VRREF | 1.18 | 1.232 | 1.28 |
RREF | 19800 | 20000 | 20200 |
IFS (mA) | 326.00 | 400 | 473.93 |
Error (%) | –18.50 | 18.48 |
Parameter | Minimum | Typical | Maximum |
---|---|---|---|
VDAC | 1.0677 | 1.0677 | 1.0677 |
ARREF | 28100 | 30000 | 31900 |
VRREF | 1.18 | 1.232 | 1.28 |
RREF | 19800 | 20000 | 20200 |
IFS (mA) | 135.35 | 200 | 267.18 |
Error (%) | –33.83 | 33.59 |
These tables show that as the IFS current level decreases, the overall error percentage increases due to increasing offset error from the internal signal chain. It is worthy to clarify that the VRREF and ARREF values in these tables are data sheet values which represent the characterization data variation across a wide range of temperatures and voltages with additional margin. For information on how to further minimize this percentage of error based on targeted characterization data for VRREF and ARREF, see Application-Specific Error Calculations.