1
Features
2
Applications
3
Description
4
Pin Configuration and Functions
5
Specifications
5.1
Absolute Maximum Ratings
5.2
ESD Ratings
5.3
Recommended Operating Conditions
5.4
Thermal Information
5.5
Electrical Characteristics
5.6
I2C Interface Voltage Level
5.7
I2C Interface Timing
5.8
Typical Characteristics
6
Detailed Description
6.1
Overview
6.2
Functional Block Diagram
6.3
Feature Description
6.3.1
The Shield
6.3.2
The CAPDAC
6.3.3
Capacitive System Offset Calibration
6.3.4
Capacitive Gain Calibration
6.4
Device Functional Modes
6.4.1
Single Ended Measurement
6.4.2
Differential Measurement
6.5
Programming
6.5.1
Serial Bus Address
6.5.2
Read/Write Operations
6.5.3
Device Usage
6.5.3.1
Measurement Configuration
6.5.3.2
Triggering Measurements
6.5.3.3
Wait for Measurement Completion
6.5.3.4
Read of Measurement Result
6.6
Register Maps
6.6.1
Registers
6.6.1.1
Capacitive Measurement Registers
6.6.2
Measurement Registers
6.6.3
Measurement Configuration Registers
6.6.4
FDC Configuration Register
6.6.5
Offset Calibration Registers
6.6.6
Gain Calibration Registers
6.6.7
Manufacturer ID Register
6.6.8
Device ID Register
7
Applications and Implementation
7.1
Application Information
7.1.1
Liquid Level Sensor
7.2
Typical Application
7.2.1
Design Requirements
7.2.2
Detailed Design Procedure
7.2.3
Application Curve
7.3
Best Design Practices
7.4
Initialization Set Up
7.5
Power Supply Recommendations
7.6
Layout
7.6.1
Layout Guidelines
7.6.2
Layout Example
8
Device and Documentation Support
8.1
Documentation Support
8.1.1
Related Documentation
8.2
Receiving Notification of Documentation Updates
8.3
Support Resources
8.4
Trademarks
8.5
Electrostatic Discharge Caution
8.6
Glossary
9
Revision History
10
Mechanical, Packaging, and Orderable Information
Package Options
Mechanical Data (Package|Pins)
DGS|10
MPDS035C
Thermal pad, mechanical data (Package|Pins)
Orderable Information
snoscz4a_oa
snoscz4a_pm
1
Features
Qualified for automotive applications
AEC-Q100 qualified with the following results
Device temperature grade 1: –40°C to 125°C ambient operating temperature range
Device HBM ESD classification level 2
Device CDM ESD classification level C5
Input range: ±15pF
Measurement resolution: 0.5fF
Maximum offset capacitance: 100pF
Programmable output rates: 100/200/400 S/s
Maximum shield load: 400pF
Supply voltage: 3.3V
Temperature range: –40° to 125°C
Current consumption:
Active: 750µA
Standby: 29µA
Interface: I
2
C
Number of channels: 4