SNOSCZ5B June 2015 – October 2024 FDC2112 , FDC2114 , FDC2212 , FDC2214
PRODUCTION DATA
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
CH3_SETTLECOUNT | |||||||
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
CH3_SETTLECOUNT | |||||||
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
15:0 | CH3_SETTLECOUNT | R/W | 0000 0000 0000 0000 | Channel 3 Conversion Settling The FDC uses this settling time to allow the LC sensor to stabilize before initiation of a conversion on Channel 3. If the amplitude has not settled prior to the conversion start, an Amplitude warning is generated if reporting of this type of warning is enabled b0000 0000 0000 0000: Settle Time (tS3)= 32 ÷ fREF3 b0000 0000 0000 0001: Settle Time (tS3)= 32 ÷ fREF3 b0000 0000 0000 0010 - b1111 1111 1111 1111: Settle Time (tS3)= (CH3_SETTLECOUNTˣ16) ÷ fREF3 |