SBOS790 April   2017 INA233

PRODUCTION DATA.  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 High-Accuracy Analog-to-Digital Convertor (ADC)
      2. 7.3.2 Interleaved Power Calculation
      3. 7.3.3 Power Accumulator and Energy Measurement
      4. 7.3.4 I2C-, SMBus-, and PMBus-Compatible Digital Interface
      5. 7.3.5 Multiple Fault Event Reporting
    4. 7.4 Device Functional Modes
      1. 7.4.1 Continuous verses Triggered Operation
      2. 7.4.2 Device Shutdown
      3. 7.4.3 Averaging and Conversion Time Considerations
      4. 7.4.4 Filtering and Input Considerations
    5. 7.5 Programming
      1. 7.5.1 Default Settings
      2. 7.5.2 Calibration Register and Scaling
      3. 7.5.3 Reading and Writing Telemetry Data and Warning Thresholds
      4. 7.5.4 Reading Telemetry Data and Warning Thresholds
        1. 7.5.4.1 Writing Telemetry Data and Warning Thresholds
      5. 7.5.5 System-Level Calibration With MFR_CALIRATION Command
      6. 7.5.6 Bus Overview
        1. 7.5.6.1 Serial Bus Address
        2. 7.5.6.2 Serial Interface
        3. 7.5.6.3 Writing to and Reading From the INA233
          1. 7.5.6.3.1 Packet Error Checking
          2. 7.5.6.3.2 Bus Timing Requirements
        4. 7.5.6.4 SMBus Alert Response
    6. 7.6 Register Maps
      1. 7.6.1 PMBus Command Support
      2. 7.6.2 Standard PMBus Commands
        1. 7.6.2.1  CLEAR_FAULTS (03h)
        2. 7.6.2.2  RESTORE_DEFAULT_ALL (12h)
        3. 7.6.2.3  CAPABILITY (19h)
        4. 7.6.2.4  IOUT_OC_WARN_LIMIT (4Ah) [default = 01111111 11111000]
        5. 7.6.2.5  VIN_OV_WARN_LIMIT (57h) [default = 01111111 11111000]
        6. 7.6.2.6  VIN_UV_WARN_LIMIT (58h) [default = 00000000 00000000]
        7. 7.6.2.7  PIN_OP_WARN_LIMIT (6Bh) [default = 11111111 11110000]
        8. 7.6.2.8  STATUS_BYTE (78h)
        9. 7.6.2.9  STATUS_WORD (79h)
        10. 7.6.2.10 STATUS_IOUT (7Bh)
        11. 7.6.2.11 STATUS_INPUT (7Ch)
        12. 7.6.2.12 STATUS_CML (7Eh)
        13. 7.6.2.13 STATUS_MFR_SPECIFIC (80h)
        14. 7.6.2.14 READ_EIN (86h)
        15. 7.6.2.15 READ_VIN (88h)
        16. 7.6.2.16 READ_IIN (89h)
        17. 7.6.2.17 READ_VOUT (8Bh)
        18. 7.6.2.18 READ_IOUT (8Ch, R)
        19. 7.6.2.19 READ_POUT (96h, R)
        20. 7.6.2.20 READ_PIN (97h, R)
        21. 7.6.2.21 MFR_ID (99h)
        22. 7.6.2.22 MFR_MODEL (9Ah)
        23. 7.6.2.23 MFR_REVISION (9Bh)
      3. 7.6.3 Manufacturer-Specific PMBus Commands
        1. 7.6.3.1 MFR_ADC_CONFIG (D0h) [default = 01000001 00100111]
        2. 7.6.3.2 MFR_READ_VSHUNT (D1h) [default = 00000000 00000000]
        3. 7.6.3.3 MFR_ALERT_MASK (D2h) [default = XXXXXXXX 11110000]
        4. 7.6.3.4 MFR_CALIBRATION (D4h) [default = 00000000 00000001]
        5. 7.6.3.5 MFR_DEVICE_CONFIG (D5h) [default = 00000010]
        6. 7.6.3.6 5.1.1 CLEAR_EIN (D6h)
        7. 7.6.3.7 TI_MFR_ID (E0h) [value = 01010100 01001001]
        8. 7.6.3.8 TI_MFR_MODEL (E1h) [value = 00110011 00110011]
        9. 7.6.3.9 TI_MFR_REVISION (E2h) [value = 01000001 00110000]
  8. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
        1. 8.2.2.1 Programming the Calibration Register
        2. 8.2.2.2 Calculating PMBus Coefficients
        3. 8.2.2.3 Programming Warning Thresholds
        4. 8.2.2.4 Calculating Returned Telemetry Values
      3. 8.2.3 Application Curves
  9. Power Supply Recommendations
  10. 10Layout
    1. 10.1 Layout Guidelines
    2. 10.2 Layout Example
  11. 11Device and Documentation Support
    1. 11.1 Device Support
      1. 11.1.1 Development Support
    2. 11.2 Documentation Support
      1. 11.2.1 Related Documentation
    3. 11.3 Receiving Notification of Documentation Updates
    4. 11.4 Community Resources
    5. 11.5 Trademarks
    6. 11.6 Electrostatic Discharge Caution
    7. 11.7 Glossary
  12. 12Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Features

  • Senses Bus Voltages From 0 V to 36 V
  • High-Side or Low-Side Sensing
  • Reports Current, Voltage, and Power
  • Integrated Power Accumulator for Energy and Average Power Monitoring
  • High Accuracy:
    • 0.1% Gain Error (Max)
    • 10-µV Offset (Max)
  • Configurable Averaging Options
  • Independent Alert Limits for Current, Bus Voltage, and Power
  • 1.8-V Compliant I2C, SMBus, PMBus Interface
  • 16 Programmable Addresses
  • Operates From a 2.7-V to 5.5-V Power Supply
  • 10-Pin, DGS (VSSOP) Package

Applications

  • Servers
  • Telecom Infrastructure
  • High-Performance Computing
  • Power Metering
  • Battery Chargers
  • Power Supply
  • Test Equipment

Description

The INA233 device is a current, voltage, and power monitor with an I2C-, SMBus-, and PMBus-compatible interface that is compliant with digital bus voltages from 1.8 V to 5.0 V. The device monitors and reports values for current, voltage, and power. The integrated power accumulator can be used for energy or average power calculations. Programmable calibration value, conversion times, and averaging when combined with an internal multiplier enable direct readouts of current in amperes and power in watts.

The INA233 senses current on common-mode bus voltages that can vary from 0 V to 36 V, independent of the supply voltage. The device operates from a single 2.7-V to 5.5-V supply, drawing a typical supply current of 310 µA in normal operation. The device can be placed in a low-power standby mode where the typical operating current is only 2 µA. The device is specified over the operating temperature range between –40°C and +125°C and features up to 16 programmable addresses.

Device Information(1)

PART NUMBER PACKAGE BODY SIZE (NOM)
INA233 VSSOP (10) 3.00 mm x 3.00 mm
  1. For all available packages, see the orderable addendum at the end of the datasheet.

High-Side or Low-Side Sensing Application

INA233 p1_fbd_sbos790.gif