SBOSAD3 may 2023 INA310A-Q1 , INA310B-Q1
PRODUCTION DATA
The INA310x-Q1 can operate only in unidirectional mode, but Figure 7-6 shows that two INA310x-Q1s can be configured to provide a bidirectional overcurrent alert signal. The polarity of the differential voltage measured across the shunt resistor is in reverse for one current sense amplifier. Two INA310x-Q1 function to cover the opposite current directions, and therefore provide bidirectional overcurrent monitor function.