SLLS983L June   2009  – October 2023 ISO1050

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Revision History
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Power Ratings
    6. 6.6  Insulation Specifications
    7. 6.7  Safety-Related Certifications
    8. 6.8  Safety Limiting Values
    9. 6.9  Electrical Characteristics - DC Specification
    10. 6.10 Switching Characteristics
    11. 6.11 Insulation Characteristics Curves
    12. 6.12 Typical Characteristics
  8. Parameter Measurement Information
  9. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 CAN Bus States
      2. 8.3.2 Digital Inputs and Outputs
      3. 8.3.3 Protection Features
        1. 8.3.3.1 TXD Dominant Time-Out (DTO)
        2. 8.3.3.2 Thermal Shutdown
        3. 8.3.3.3 Undervoltage Lockout and Fail-Safe
        4. 8.3.3.4 Floating Pins
        5. 8.3.3.5 CAN Bus Short-Circuit Current Limiting
    4. 8.4 Device Functional Modes
  10. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
        1. 9.2.2.1 Bus Loading, Length and Number of Nodes
        2. 9.2.2.2 CAN Termination
      3. 9.2.3 Application Curve
  11. 10Power Supply Recommendations
    1. 10.1 General Recommendations
    2. 10.2 Power Supply Discharging
  12. 11Layout
    1. 11.1 Layout Guidelines
      1. 11.1.1 PCB Material
    2. 11.2 Layout Example
  13. 12Device and Documentation Support
    1. 12.1 Documentation Support
      1. 12.1.1 Related Documentation
    2. 12.2 Receiving Notification of Documentation Updates
    3. 12.3 Support Resources
    4. 12.4 Trademarks
    5. 12.5 Electrostatic Discharge Caution
    6. 12.6 Glossary
  14. 13Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Safety-Related Certifications

VDE CSA UL CQC TUV
Certified according to DIN EN IEC 60747-17 (VDE 0884-17) Certified according to IEC 60950-1 and IEC 62368-1 Certified according to UL 1577 Component Recognition Program Certified according to
GB4943.1-2011
Certified according to EN 61010-1 and EN 62368-1
Basic Insulation
Transient Overvoltage,
4000 VPK
Surge Voltage, 4000 VPK
Maximum Working
Voltage, 1200 VPK
(ISO1050DW) and
560 VPK (ISO1050DUB)
ISO1050DW:
5000 VRMS Reinforced Insulation
Working voltage of 380 VRMS per
IEC 60950-1 2nd Ed.+A1+A2 and
IEC 62368-1:2014
Working voltage of 300 VRMS per
IEC 61010-1 3rd Ed.
ISO1050DUB:
2500 VRMS Basic Insulation
Working voltage of 700 VRMS per
IEC 60950-1 2nd Ed.+A1+A2
Working voltage of 600 VRMS per
IEC 61010-1 3rd Ed. and IEC
62368-1:2014
ISO1050DUB: 2500 VRMS
Single Protection
ISO1050DW: 4243 VRMS
Single Protection
ISO1050DW:
Reinforced Insulation,
Altitude ≤ 5000 m, Tropical
Climate, 250 VRMS
maximum working voltage
ISO1050DW:
5000 VRMS Reinforced Insulation,
400 VRMS maximum working
voltage
5000 VRMS Basic Insulation,
600 VRMS maximum working
voltage
ISO1050DUB:
2500 VRMS Reinforced Insulation,
400 VRMS maximum working
voltage
2500 VRMS Basic Insulation,
600 VRMS maximum working
voltage
Certificate number:
40047657
Client ID number: 77311 Master contract number: 220991 File number: E181974 Certificate number:
CQC14001109541