SLLS897F march   2008  – august 2023 ISO1176

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Revision History
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Power Ratings
    6. 6.6  Insulation Specifications
    7. 6.7  Safety-Related Certifications
    8. 6.8  Safety Limiting Values
    9. 6.9  Electrical Characteristics: Driver
    10. 6.10 Electrical Characteristics: Receiver
    11. 6.11 Supply Current
    12. 6.12 Electrical Characteristics: ISODE-Pin
    13. 6.13 Switching Characteristics: Driver
    14. 6.14 Switching Characteristics: Receiver
    15. 6.15 Insulation Characteristics Curves
    16. 6.16 Typical Characteristics
  8. Parameter Measurement Information
  9. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Device Functional Modes
  10. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
        1. 9.2.2.1 Transient Voltages
        2. 9.2.2.2 ISO1176 “Sticky Bit” Issue (Under Certain Conditions)
      3. 9.2.3 Application Curve
  11. 10Power Supply Recommendations
  12. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  13. 12Device and Documentation Support
    1. 12.1 Documentation Support
      1. 12.1.1 Related Documentation
    2. 12.2 Support Resources
    3. 12.3 Trademarks
    4. 12.4 Electrostatic Discharge Caution
    5. 12.5 Glossary
  14. 13Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Features

  • Meets or exceeds the requirements of
    EN 50170 and TIA/EIA-485-A
  • Signaling rates up to 40 Mbps
  • Differential output exceeds 2.1 V (54 Ω load)
  • Low bus capacitance – 10 pF (maximum)
  • Up to 160 transceivers on a bus
  • 50 kV/μs typical transient immunity
  • Fail-safe receiver for bus open, short, idle
  • 3.3 V inputs are 5 V tolerant
  • Bus-pin ESD protection
    • 16 kV HBM between bus pins and GND2
    • 6 kV HBM between bus pins and GND1
  • Safety and regulatory approvals
    • 4000 VPK isolation, 560 VPK VIORM per DIN EN IEC 60747-17 (VDE 0884-17)
    • 2500 VRMS isolation rating per UL 1577
    • 4000 VPK isolation rating per CSA 62368-1