SLOS580H
may 2008 – august 2023
ISO15
,
ISO35
PRODUCTION DATA
1
1
Features
2
Applications
3
Description
4
Revision History
5
Pin Configuration and Functions
6
Specifications
6.1
Absolute Maximum Ratings
6.2
ESD Ratings
6.3
Recommended Operating Conditions
6.4
Thermal Information
6.5
Power Ratings
6.6
Insulation Specifications
6.7
Safety-Related Certifications
6.8
Safety Limiting Values
6.9
Electrical Characteristics: Driver
6.10
Electrical Characteristics: Receiver
6.11
Supply Current
6.12
Switching Characteristics: Driver
6.13
Switching Characteristics: Receiver
6.14
Insulation Characteristics Curves
6.15
Typical Characteristics
7
Parameter Measurement Information
8
Detailed Description
8.1
Overview
8.2
Functional Block Diagrams
8.3
Device Functional Modes
8.3.1
Device I/O Schematics
9
Application and Implementation
9.1
Application Information
9.2
Typical Application
9.2.1
Design Requirements
9.2.2
Detailed Design Procedure
9.2.3
Application Curve
Power Supply Recommendations
10
Layout
10.1
Layout Guidelines
10.2
Layout Example
11
Device and Documentation Support
11.1
Documentation Support
11.1.1
Related Documentation
11.2
Receiving Notification of Documentation Updates
11.3
Support Resources
11.4
Trademarks
11.5
Electrostatic Discharge Caution
11.6
Glossary
13
Mechanical, Packaging, and Orderable Information
Package Options
Mechanical Data (Package|Pins)
DW|16
MSOI003I
Thermal pad, mechanical data (Package|Pins)
Orderable Information
slos580h_oa
slos580h_pm
1
Features
Meets or exceeds TIA/EIA RS-485 requirements
1/8 unit load – Up to 256 nodes on a bus
Signaling rates up to 1 Mbps
Thermal shutdown protection
Low bus capacitance – 16 pF (typical)
50 kV/μs typical transient immunity
Fail-safe receiver for bus open, short, idle
3.3-V inputs are 5-V tolerant
Safety and regulatory approvals
4000-V
PK
V
IOTM
, 560-V
PK
V
IORM
per DIN EN IEC 60747-17 (VDE 0884-17)
2500 V
RMS
isolation rating per UL 1577
2500 V
RMS
isolation rating per CSA 62368-1.