4 Revision History
Changes from Revision A (March 2021) to Revision B (Febuary 2023)
- Changed standard name From: "DIN V VDE V 0884-11:2017-01" To: "DIN EN IEC
60747-17 (VDE 0884-17)" throughout the document Go
- Updated CMTI From: "50 kV/us (min) and 75 kV/us (typ)" To: "100 kV/us (min)
and 150 kV/us (typ)" throughout the documentGo
- Removed references to standard IEC/EN/CSA 60950-1 throughout the
documentGo
- Removed standard revision and year references as well as "certification
pending" references from all standard names throughout the document Go
- Changed test conditions and value of Maximum surge isolation voltage
(VIOSM) From: "6250 VPK" To: "10000 VPK" throughout
document as per DIN EN IEC 60747-17 (VDE 0884-17)Go
- Updated VIORM From: "1500 VPK" To: "2121 VPK" to match VDE certificate Go
- Updated VIOWM From: "1060 VRMS" To: "1500
VRMS" and From: "1500 VDC" To: "2121 VDC" throughout
the documentGo
- Added Maximum impulse voltage (VIMP) specification in Insulation Specifications per DIN EN IEC 60747-17 (VDE 0884-17) Go
- Clarified method b test conditions of Apparent charge (qPD) in Insulation Specification Go
- Changed working voltage lifetime margin From: "87.5%" To: "50%", minimum
required insulation lifetime From: "37.5 years" To: "30 years" and insulation lifetime per
TDDB From: "220 years" To: "36 years" in Section 9.2.3.1
per DIN EN IEC 60747-17 (VDE 0884-17) Go
- Changed Figure 9-8 per DIN EN IEC 60747-17 (VDE 0884-17)Go
Changes from Revision * (January 2021) to Revision A (March 2021)