4 Revision History
Changes from Revision F (May 2022) to Revision G (February 2023)
- Changed standard name from "DIN V VDE V 0884-11:2017-01" to "DIN EN
IEC 60747-17 (VDE 0884-17)" throughout the documentGo
- Removed references to standard IEC/EN/CSA 60950-1 throughout the
documentGo
- Removed standard revision and year references from all standard
names thoughout the documentGo
- Added Maximum impulse voltage VIMP specification per DIN EN IEC 60747-17 (VDE 0884-17)Go
- Changed test conditions and values of Maximum surge isolation voltage (VIOSM) specification per DIN EN IEC 60747-17 (VDE 0884-17)Go
- Clarified method b test conditions of Apparent charge (qPD)Go
- Changed maximum surge isolation voltage from 6250 VPK to 10000 VPK
Go
- Changed working voltage lifetime margin from 87.5% to 50%, minimum required
insulation lifetime from 37.5 years to 30 years, and insulation lifetime per TDDB from 135
years to 36 years per DIN EN IEC 60747-17 (VDE 0884-17)Go
- Changed Figure 10-8 per DIN EN IEC 60747-17 (VDE 0884-17)Go
Changes from Revision E (June 2021) to Revision F (May 2022)
- Updated CMTI typical to 150 kV/us and minimum to 100
kV/usGo
Changes from Revision D (March 2021) to Revision E (June 2021)
- Updated high lifetime working voltage.Go
- Insulation Specifications table 7.6 has been updated with VIOWM
1500Vrms, VIORM at 2121Vpk.Go
- Updated Safety-Related Certification table.Go
- Updated switching characteristics tables with test conditions for
"Default output delay time from input power loss" line item.Go
- Switched the labels for VCC1 falling and VCC2 rising in the graph legend of Power Supply Undervoltage Threshold vs Free-Air Temperature
Go
- Updated Typical Application diagram to reflect
5.5Viso.Go
- Updated Insulation Lifetime Projection Data image.Go
- Updated SN6505A reference with SN6505B in Power Supply
Recommendations.Go
Changes from Revision C (January 2021) to Revision D (March 2021)
- Added ISO6742 data under SpecificationsGo
Changes from Revision B (December 2020) to Revision C (January 2021)
- Added ISO674x to data sheet. Go
Changes from Revision A (October 2020) to Revision B (December 2020)
- Updated device status to Production DataGo
Changes from Revision * (August 2020) to Revision A (October 2020)