See(1)
|
VALUE |
UNIT |
VCC |
Supply voltage(2), VCC1, VCC2 |
–0.5 to 6 |
V |
VI |
Voltage at IN, OUT, EN |
–0.5 to 6 |
V |
IO |
Output current |
±15 |
mA |
ESD |
Electrostatic discharge |
Human Body Model |
All pins |
±4 |
kV |
Field-Induced-Charged Device Model |
±1 |
TJ |
Maximum junction temperature |
150 |
°C |
(1) Operation outside the Absolute Maximum Ratings may cause permanent device damage. Absolute Maximum Ratings do not imply functional operation of the device at these or any other conditions beyond those listed under Recommended Operating Conditions. If used outside the Recommended Operating Conditions but within the Absolute Maximum Ratings, the device may not be fully functional, and this may affect device reliability, functionality, performance, and shorten the device lifetime.
(2) All voltage values except differential I/O bus voltages are with respect to the local ground terminal (GND1 or GND2) and are peak voltage values.