4 Revision History
Changes from Revision B (October 2020) to Revision C (December 2023)
- Changed standard name from: "DIN V VDE V 0884-11:2017-01" to: "DIN
EN IEC 60747-17 (VDE 0884-17)" throughout the documentGo
- Removed references to standard IEC/EN/CSA 60950-1 throughout the
documentGo
- Removed standard revision and year references from all standard
names throughout the documentGo
- Updated numbering format for tables, figures and cross-references
throughout document.Go
- Updated Thermal Characteristics, Safety Limiting Values, and Thermal
Derating Curves to provide more accurate system-level thermal
calculations.Go
- Updated electrical and switching characteristics to match device
performance.Go
- Updated Climatic category for D packageGo
- Updated Maximum working voltages for DW-16 and D-8Go
- Changed working voltage lifetime margin from: 87.5% to: 50%, minimum
required insulation lifetime from: 37.5 years to: 30 years and insulation
lifetime per TDDB from: 135 years to: 169 years per DIN EN IEC 60747-17 (VDE
0884-17)Go
- Changed Figure 9-6 per DIN EN
IEC 60747-17 (VDE 0884-17)Go
Changes from Revision A (April 2020) to Revision B (October 2020)
- Added Functional Safety bulletsGo
- Added D-8 values for TUV columnGo
- Changed minimum CMTI value from 40 kV/μs to 85 kV/μs throughout the documentGo
Changes from Revision * (March 2016) to Revision A (April 2020)
- Made editorial and cosmetic changes throughout the document Go
- Changed From: "Isolation Barrier Life: >40 Years" To:">100-Year Projected Lifetime at 1.5 kVRMS Working Voltage" in Section 1
Go
- Added "Up to 5000 VRMS Isolation Rating" in Section 1
Go
- Added "Up to 12.8 kV Surge Capability" in Section 1
Go
- Added "±8 kV IEC 61000-4-2 Contact Discharge Protection across Isolation Barrier" in Section 1
Go
- Updated certification-related bullets in Section 1 and changed VDE standard name From: DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 To: DIN VDE V 0884-11:2017-01 throughout the documentGo
- Updated Section 2 listGo
- Updated Figure 3-1 to show two isolation capacitors in series per channel instead of a single
isolation capacitor Go
- Added Climatic category to tableGo
- Updated CSA column and changed DW package to (DW-16)Go
- Changed tie TYP value from 1.5 to 1 throughout the documentGo
- Switched the line colors for VCC at 2.5 V and VCC at 3.3 V in the Low-Level Output Voltage vs Low-Level Output Current graphGo
- Deleted EN from the Common-Mode Transient Immunity Test Circuit figureGo
- Corrected ground symbols for "Input (Devices with F suffix)" in Section 8.4.1
Go
- Added Section 9.2.3.1 sub-section under Section 9.2.3 section Go
- Added 'How to use isolation to improve ESD, EFT and Surge immunity in industrial systems' application report to Section 12.2 section Go