4 Revision History
Changes from * Revision (December 2014) to A Revision
- Changed ESD values from 1000 to 2000 and from 250 to 750 on both packages.Go
- Added logic levels for ADDR, INTB, and SD pins.Go
- Changed description of clocking architecture for improved clarity. Go
- Changed register names and field names from CHx_NAME and NAME_CHx to NAMEx. Go
- Added instructions on setting registers with both R and R/W fields.Go
- Changed register names from DATA_CHx to DATAx; and CHx_ERR_YY field names to ERR_YYx.Go
- Changed ERR_AE field description on DATA0, DATA1, DATA2 and DATA3 tables.Go
- Changed register names from RCOUNT_CHx to RCOUNTx; and CHx_RCOUNT field names to RCOUNTx Go
- Changed register names from OFFSET_CHx to OFFSETx; and CHx_OFFSET field names to OFFSETx Go
- Changed register names from SETTLECOUNT_CHx to SETTLECOUNTx; and CHx_SETTLECOUNT field names to SETTLECOUNTx Go
- Changed Address of SETTLECOUNT0 and SETTLECOUNT1 were not correct on table. Go
- Changed register names from CLOCK_DIVIDERS_CHx to CLOCK_DIVIDERSx; CHx_FIN_DIVIDER field names to FIN_DIVIDERx, and CHx_FREF_DIVIDER field names to FREF_DIVIDERx. Go
- Changed CHx_UNREADCONV field names to UNREADCONVx Go
- Changed register names from DRIVE_CURRENT_CHx to DRIVE_CURRENTx; CHx_IDRIVE field names to IDRIVEx, and CHx_INIT_IDRIVE to INIT_IDRIVEx Go
- Changed Application Information section for clarity, and provided additional information on device configuration and operation. Go
- Added instructions for using an oscilloscope to configure sensor drive currentGo
- Changed description of clocking usage for clarity. Go
- Changed reference frequency limits from < to ≤Go
- Changed to a ≥ symbol in the Clock Configuration Requirements table. Go