SNVSC10 March 2022 LM25143
PRODUCTION DATA
The LM25143 includes an internal junction temperature monitor. If the temperature exceeds 175°C (typical), thermal shutdown occurs. When entering thermal shutdown, the device:
This is a non-latching protection, and as such, the device cycles into and out of thermal shutdown if the fault persists.