SNVS479H January 2007 – August 2017 LM25575
PRODUCTION DATA.
RT sets the oscillator switching frequency. Generally, higher frequency applications are smaller but have higher losses. Operation at 300 kHz was selected for this example as a reasonable compromise for both small size and high efficiency. The value of RT for 300 kHz switching frequency can be calculated Equation 4:
The nearest standard value of 21 kΩ was chosen for RT.