SNVSB14C April 2018 – October 2021 LM5036
PRODUCTION DATA
The soft-start delay tD(SS) , which is the time it takes for the soft-start capacitor to rise from 0 V to VSSSecEn (2.06-V typical), can be programmed with the SS capacitor value according to Equation 52
where