SNVSBT5 November   2023 LM5185

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Description (continued)
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Typical Characteristics
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1  Power MOSFET Gate Driver
      2. 7.3.2  PSR Flyback Modes of Operation
      3. 7.3.3  High Voltage VCC Regulator
      4. 7.3.4  Setting the Output Voltage
        1. 7.3.4.1 Diode Thermal Compensation
      5. 7.3.5  Control Loop Error Amplifier
      6. 7.3.6  Precision Enable
      7. 7.3.7  Configurable Soft Start
      8. 7.3.8  Minimum On-Time and Off-Time
      9. 7.3.9  Current Sensing and Overcurrent Protection
      10. 7.3.10 Thermal Shutdown
    4. 7.4 Device Functional Modes
      1. 7.4.1 Shutdown Mode
      2. 7.4.2 Standby Mode
      3. 7.4.3 Active Mode
  9. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Applications
      1. 8.2.1 Design 1: Wide VIN, Low IQ PSR Flyback Converter Rated at 16.4 V, 1 A
        1. 8.2.1.1 Design Requirements
        2. 8.2.1.2 Detailed Design Procedure
          1. 8.2.1.2.1  Custom Design With WEBENCH® Tools
          2. 8.2.1.2.2  Custom Design With Excel Quickstart Tool
          3. 8.2.1.2.3  Flyback Transformer T1 and Current-Sense Resistor (RCS)
          4. 8.2.1.2.4  Flyback Diode – DFLY
          5. 8.2.1.2.5  Leakage Inductance Clamp Circuit – DF, DCLAMP
          6. 8.2.1.2.6  Feedback Resistor – RFB
          7. 8.2.1.2.7  Thermal Compensation Resistor – RTC
          8. 8.2.1.2.8  UVLO Resistors – RUV1, RUV2
          9. 8.2.1.2.9  Soft-Start Capacitor – CSS
          10. 8.2.1.2.10 Compensation Components
        3. 8.2.1.3 Application Curves
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Examples
  10. Device and Documentation Support
    1. 9.1 Device Support
      1. 9.1.1 Development Support
        1. 9.1.1.1 Custom Design With WEBENCH® Tools
    2. 9.2 Documentation Support
      1. 9.2.1 Related Documentation
    3. 9.3 Receiving Notification of Documentation Updates
    4. 9.4 Support Resources
    5. 9.5 Trademarks
    6. 9.6 Electrostatic Discharge Caution
    7. 9.7 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Precision Enable

The precision EN/UVLO input supports adjustable input undervoltage lockout (UVLO) with hysteresis for application specific power-up and power-down requirements. EN/UVLO connects to a comparator with a 1.5-V reference voltage and 50-mV hysteresis. An external logic signal can be used to drive the EN/UVLO input to toggle the output on and off for system sequencing or protection. The simplest way to enable the LM5185 is to connect EN/UVLO directly to VIN. This connection allows the LM5185 to start up when VIN is within the valid operating range. However, many applications benefit from using resistor divider RUV1 and RUV2 as shown in Figure 7-4 to establish a precision UVLO level.

GUID-20230524-SS0I-QV50-NQ4C-LPNFNQD5BKH1-low.svg Figure 7-4 Programmable Input Voltage UVLO With Hysteresis

Use Equation 10 and Equation 11 to calculate the input UVLO voltages turn-on and turn-off voltages, respectively.

Equation 10. VINON=VUV-RISING×(1+RUV1RUV2)

where

  • VUV-RISING and VUV-FALLING are the UVLO comparator thresholds
  • IUV-HYST is the hysteresis current
Equation 11. VINOFF=VUV-FALLING×1+RUV1RUV2-IUV-HYST×RUV1

The LM5185 also provides a low-IQ shutdown mode when the EN/UVLO voltage is pulled below a base-emitter voltage drop (approximately 0.6 V at room temperature). If the EN/UVLO voltage is below this hard shutdown threshold, the internal LDO regulator powers off, and the internal bias-supply rail collapses, shutting down the bias currents of the LM5185. The LM5185 operates in standby mode when the EN/UVLO voltage is between the hard shutdown and precision-enable thresholds.