The LM94 monitoring function is started as soon as the part is powered up. The LM94 performs a “round robin” sampling of the inputs, in the order shown below. Each cycle of the round robin is completed in less than 100 ms.
The results of the sampling and conversions can be found in the value registers and are available at any time.
Channel # | Input | Typical Assignment |
---|---|---|
3 | Temp Zone 3 | Internal Temperature Reading |
1 | Temp Zone 1a | Remote Diode 1a Temp Reading |
Temp Zone 1b | Remote Diode 1b Temp Reading (if selected) | |
2 | Temp Zone 2a | Remote Diode 2a Temp Reading |
Temp Zone 2b | Remote Diode 2b Temp Reading (if selected) | |
4 | AIN1 | +12V1 (if selected) |
5 | AIN2 | +12V2 (if selected) |
6 | AIN3 | +12V3 |
7 | AIN4 | FSB_Vtt |
8 | AIN5 | 3GIO/PXH/MCH_Core |
9 | AIN6 | ICH_Core |
10 | AIN7 | CPU_1Vccp |
11 | AIN8 | CPU2_Vccp |
12 | AIN9 | 3.3V |
13 | AIN10 | +5V |
14 | AIN11 | SCSI_Core |
15 | AIN12 | Mem_Core |
16 | AIN13 | Mem_Vtt |
17 | AIN14 | GBIT_Core |
18 | AIN15 | −12V |
19 | AIN16 | 3.3V SB VDD Supply Rail |