SNAS264D April 2006 – February 2024 LM94
PRODUCTION DATA
The PWM output can operate at lower frequencies, instead of the default 22.5 kHz. The lower frequencies can be enabled through the PWMx Control 4 registers. Operating in the lower frequency mode, enables an alternate mapping of step numbers to duty cycle. This effects the auto fan control and all LM94 registers that describe a duty cycle using a 4-bit value. This alternate mapping can also be enable when using the default 22.5 kHz PWM frequency.
The alternate LUT PWM duty cycle mapping is listed in the following table:
4-Bit Value | LUT Step | Alternate LUT Duty Cycle |
---|---|---|
0h | 0% | |
1h | 1 | 25.00% |
2h | 2 | 28.57% |
3h | 3 | 32.14% |
4h | 4 | 35.71% |
5h | 5 | 39.29% |
6h | 6 | 42.86% |
7h | 7 | 46.43% |
8h | 8 | 50.00% |
9h | 9 | 53.57% |
Ah | 10 | 57.14% |
Bh | 11 | 71.43% |
Ch | 12 | 85.71% |
Dh | 13 | 100.00% |
Eh | — | Reserved |
Fh | — | Reserved |