SNAS264D April 2006 – February 2024 LM94
PRODUCTION DATA
LM94 is designed to be used primarily in dual processor server systems that may require only one monitoring device.
If multiple LM94 devices are implemented in a system, they must have unique SMBus slave addresses. See the Section 6.3.1.1 for more information.
The board designer may apply a 10 kΩ pull-down and/or pull-up resistors to ground and/or to 3.3V SB VDD on the ADDR_SEL pin. The LM94 is designed to work with resistors of 5% tolerance for the case where two resistors are required. Upon the first SMBus communication to the part, the LM94 assigns itself an SMBus address according to the ADDR_SEL input.
Address Select | Board Implementation | SMBus Address |
---|---|---|
less-than 10% of VDD | Pulled to ground through a 10 kΩ resistor | 0101 100b |
≈ VDD/2 | 10 kΩ (5%) Resistor to 3.3V SB VDD and to Ground | 0101 110b |
greater-than 90% of VDD | Pulled to 3.3V SB VDD through a 10 kΩ resistor | 0101 101b |