7.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted) (1)(2)(3)
|
MIN |
MAX |
UNIT |
VCC |
Supply voltage (4) |
–0.3 |
3.6 |
V |
VIN |
Input voltage |
–0.3 |
(VCC + 0.3) |
V |
TL |
Lead temperature (solder 4 seconds) |
|
+260 |
°C |
TJ |
Junction temperature |
|
150 |
°C |
IIN |
Differential input current (CLKinX/X*,
OSCin/OSCin*) |
|
±5 |
mA |
MSL |
Moisture sensitivity level |
|
3 |
|
Tstg |
Storage temperature |
–65 |
150 |
°C |
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) This device is a high performance RF integrated circuit with an ESD rating up to 2-kV Human Body Model, up to 150-V Machine Model, and up to 250-V Charged Device Model and is ESD-sensitive. Handling and assembly of this device should only be done at ESD-free workstations.
(3) Stresses in excess of the absolute maximum ratings can cause permanent or latent damage to the device. These are absolute stress ratings only. Functional operation of the device is only implied at these or any other conditions in excess of those given in the operation sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability.
(4) Never to exceed 3.6 V.