SNAS771A December 2018 – December 2018 LMK05318
PRODUCTION DATA.
Refer to the PDF data sheet for device specific package drawings
Figure 47 to Figure 51 show the recommended output interfacing and termination circuits. Unused clock outputs can be left floating and powered down by programming.
If HCSL Internal Termination (50-Ω to GND) is enabled, short 33-Ω and remove 50-Ω external resistors. |