SNAS828A february 2022 – june 2023 LMK1D1208I
PRODUCTION DATA
The outputs of Bank 0 and Bank 1 can be one of three options: logic low, buffered IN0, or buffered IN1. These output types should only be attained by maintaining the register setting combination outlined in Table 9-3. The LMK1D1208I registers must be programmed within these possible logic states to ensure proper device functionality. Using the device outside the intended logic can result in degraded performance.
BANKx OUTPUTS | BANKx_IN_SEL | BANKx_MUTE | IN0_EN | IN1_EN |
---|---|---|---|---|
Logic low | X | 1 | X | X |
IN0 | 1 | 0 | 1 | X |