SNOSB29H November 2009 – May 2022 LMP8645 , LMP8645HV
PRODUCTION DATA
Figure 8-2 shows the resulting circuit voltages with the input load swept from 0 A to 1 A, with RGAIN= 13 kΩ for operation in Range 1 (preferring accuracy over all load operating conditions).
Also shown in Figure 8-3 is the resulting output voltage with RGAIN = 33 kΩ for operation in Range 3 (sacrificing low load supply accuracy while optimizing overall resolution at normal load operating conditions).