SNAS800B July 2021 – February 2024 LMX1204
PRODUCTION DATA
Table 6-18 shows the different modes for the device. The CLK_MUX field allows the user to configure the device as a buffer, divider, or multiplier. The SYSREF can also be enabled as well for applications that need this feature.
CLK_MUX | CLK_DIV / CLK_MULT | SYSREF_EN | FUNCTIONAL MODE |
---|---|---|---|
1 | x | 0 | Buffer |
1 | Buffer w/SYSREF | ||
2 | 2,3,4,..,8 | 0 | Divider |
1 | Divider w/SYSREF | ||
3 | 2,3,4 | 0 | Multiplier |
1 | Multiplier w/SYSREF |