SNAS850 December 2024 LMX1205
ADVANCE INFORMATION
The clock multiplier can be used to multiply up the input clock frequency by a factor of ×2, ×3, ×4, ×5, ×6, ×7 or ×8. The multiply value is set by the CLK_MULT field. As the multiplier is PLL-based and includes an integrated VCO, the multiplier has a state machine clock, requires calibration and has a lock detect feature.