7.4.1 Modes of Operation
SHUTDOWN:The V(NRST) voltage is below threshold level. All switch, reference, control and bias circuitry of the LP8758-E3 device are turned off.
WAIT-ON:The V(NRST) voltage is above threshold level. The reference and bias circuitry are enabled. The converter cores of the LP8758-E3 device are turned off.
READ OTP:The main supply voltage V(VANA) is above VANAUVLO level and V(NRST) voltage is above threshold level. The converter cores are disabled and the reference and bias circuitry of the LP8758-E3 are enabled. The OTP bits are loaded to registers.
STANDBY:The main supply voltage V(VANA) is above VANAUVLO level and V(NRST) voltage is above threshold level. The converter cores are disabled and the reference, control and bias circuitry of the LP8758-E3 are enabled. All registers can be read or written by the host processor through the system serial interface. The converter cores can be enabled if needed.
ACTIVE:The main supply voltage V(VANA) is above VANAUVLO level and V(NRST) voltage is above threshold level. At least one converter core is enabled. All registers can be read or written by the host processor through the system serial interface.
The operating modes and transitions between the modes are shown in Figure 12.