over operating free-air temperature (unless otherwise noted)(1) | MIN | MAX | UNIT |
---|
VI | Input voltage(2) | –0.5 | 7 | V |
VI/O | Input/output voltage(2) | –0.5 | 7 | V |
| Continuous channel current | | 128 | mA |
IIK | Input clamp current | VI < 0 | | –50 | mA |
TJ | Junction Temperature | | 150 | °C |
Tstg | Storage temperature range | –65 | 150 | °C |
(1) Operation outside the Absolute Maximum Ratings may cause permanent
device damage. Absolute Maximum Ratings do not imply functional operation
of the device at these or any other conditions beyond those listed under
Recommended Operating Conditions. If used outside the Recommended
Operating Conditions but within the Absolute Maximum Ratings, the
device may not be fully functional, and this may affect device reliability,
functionality, performance, and shorten the device lifetime.
(2) The input and input or output negative-voltage ratings may be exceeded if the
input and input or output clamp-current ratings are observed.