SLLS707B January   2006  – December 2023 MAX3223E

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Specifications
    1. 4.1 Absolute Maximum Ratings
    2. 4.2 Recommended Operating Conditions
    3. 4.3 ESD Ratings
    4. 4.4 ESD Ratings - IEC Specifications
    5. 4.5 Thermal Information
    6. 4.6 Electrical Characteristics
    7. 4.7 Driver Section
      1. 4.7.1 Electrical Characteristics
      2. 4.7.2 Switching Characteristics
      3. 4.7.3 ESD Protection
    8. 4.8 Receiver Section
      1. 4.8.1 Electrical Characteristics
      2. 4.8.2 Switching Characteristics
      3. 4.8.3 ESD Protection
    9. 4.9 Auto-Powerdown Section
      1. 4.9.1 Electrical Characteristics
      2. 4.9.2 Switching Characteristics
  6. Parameter Measurement Information
  7. Detailed Description
    1. 6.1 Functional Block Diagram
    2. 6.2 Device Functional Modes
  8. Application and Implementation
    1. 7.1 Typical Application
      1. 7.1.1 Detailed Design Procedure
  9. Device and Documentation Support
    1. 8.1 Receiving Notification of Documentation Updates
    2. 8.2 Support Resources
    3. 8.3 Trademarks
    4. 8.4 Electrostatic Discharge Caution
    5. 8.5 Glossary
  10. Revision History
  11. 10Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Absolute Maximum Ratings

over operating free-air temperature range (unless otherwise noted) (1)
MIN MAX UNIT
VCC Supply voltage range –0.3 6 V
V+ Positive-output supply voltage range(2) –0.3 7 V
V– Negative-output supply voltage range(2) 0.3 –7 V
V+ – V– Supply voltage difference(2) 13 V
VI Input voltage range Driver ( FORCEOFF, FORCEON, EN) –0.3 6 V
Receiver –25 25
VO Output voltage range Driver –13.2 13.2 V
Receiver ( INVALID) –0.3 VCC + 0.3
TJ Operating virtual junction temperature 150 °C
Tstg Storage temperature range –65 150 °C
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
All voltages are with respect to network GND.