SLLS097D June   1980  – October 2023 MC3486

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 Recommended Operating Conditions
    3. 5.3 Thermal Resistance Characteristics
    4. 5.4 Electrical Characteristics
    5. 5.5 Switching Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Device Functional Modes
  9. Device and Documentation Support
    1. 8.1 Receiving Notification of Documentation Updates
    2. 8.2 Support Resources
    3. 8.3 Trademarks
    4. 8.4 Electrostatic Discharge Caution
    5. 8.5 Glossary
  10. Revision History
  11. 10Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • NS|16
  • N|16
  • D|16
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Electrical Characteristics

over recommended ranges of common-mode input voltage, supply voltage, and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN MAX UNIT
VIT+ Differential input high-threshold voltage VO = 2.7 V, IO = -0.4 mA 0.2 V
VIT - Differential input low-threshold voltage VO = 0.5 V, IO = -8 mA - 0.2(1) V
VIK Enable-input clamp voltage II = -10 mA -1.5 V
VOH High-level output voltage VID = 0.4 V, See Note 4 and Figure 6-1 IO = -0.4 mA, 2.7 V
VOL Low-level output voltage VID = - 0.4 V, See Note 4 and Figure 6-1 IO = 8 mA, 0.5 V
IOZ High-impedance-state output current VIL = 0.8 V, VID = -3 V, VO = 2.7 V 40 μA
VIL = 0.8 V, VID = 3 V, VO = 0.5 V -40
IIB Differential-input bias current VCC = 0 V or 2.25 V, Other inputs at 0 V VI = -10 V -3.25 mA
VI = - 3 V -1.5
VI = 3 V 1.5
VI = 10 V 3.25
IIH High-level enable input current VI = 2.25 V 100 μA
VI = 2.7 V 20
IIL Low-level enable input current VI = - 0.5 V -100 μA
IOS Short-circuit output current VID = 3 v, VO = 0, See Note 5 -15 -100 mA
ICC Supply current VIL = 0 85 mA
The algebraic convention, in which the least positive (most negative) limit is designated as minimum, is used in this data sheet for threshold voltages only.
Refer to ANSI Standards TIA/EIA-422-B and TIA/EIA-423-B for exact conditions.
Only one output should be shorted at a time.