SLLSFX9 December 2024 MCF8316D
PRODUCTION DATA
MCF8316D provides an option of regulating the (input DC) power instead of motor speed for a closed loop power control. Input power regulation (instead of motor speed) mode is selected by setting INPUT_REFERENCE_MODE to 01b. The maximum power that MCF8316D can draw from the DC input supply is set by MAX_POWER. The Kp and Ki coefficients for power loop are configured through SPD_LOOP_KP and SPD_LOOP_KI.
POWER_REF (W) = DUTY_CMD (%) x MAX_POWER (W)