SLLSFQ3 January 2023 MCT8329A
PRODUCTION DATA
MCT8329A has features to decelerate the motor quickly. #GUID-8507C27A-1151-4952-BB05-6C2BCA20606E shows phase current and motor electrical speed waveform when the motor decelerates from 100% duty cycle to 10% duty cycle. Time taken for the motor to decelerate from 100% duty cycle to 10% duty cycle when fast deceleration is disabled is around 10 seconds. #GUID-8A3B4092-6DC4-484F-8C4B-09D16BDCFC8B shows phase current and motor electrical speed waveform when the motor decelerates from 100% duty cycle to 10% duty cycle. Time taken for the motor to decelerate from 100% duty cycle to 10% duty cycle when fast deceleration is enabled is around 1.5 seconds.