SLAS815D November 2012 – September 2018 MSP430F67451 , MSP430F67461 , MSP430F67471 , MSP430F67481 , MSP430F67491 , MSP430F67651 , MSP430F67661 , MSP430F67671 , MSP430F67681 , MSP430F67691 , MSP430F67751 , MSP430F67761 , MSP430F67771 , MSP430F67781 , MSP430F67791
PRODUCTION DATA.
PARAMETER | MIN | MAX | UNIT | |
---|---|---|---|---|
tSwitch | Time from occurrence of trigger (SVM or software) to "new" supply connected to system supplies | 100 | ns | |
tRecover | "Recovery time" after a switch over took place. During that time no further switching takes place. | 170 | 480 | µs |