SBOS826D
December 2017 – October 2019
OPA207
PRODUCTION DATA.
1
Features
2
Applications
3
Description
Device Images
Ultra-Low 0.1-Hz to 10-Hz Noise
4
Revision History
5
Pin Configuration and Functions
Pin Functions
6
Specifications
6.1
Absolute Maximum Ratings
6.2
ESD Ratings
6.3
Recommended Operating Conditions
6.4
Thermal Information
6.5
Electrical Characteristics
6.6
Typical Characteristics
7
Detailed Description
7.1
Overview
7.2
Functional Block Diagram
7.3
Feature Description
7.3.1
Operating Voltage
7.3.2
Input Protection
7.3.3
ESD Protection
7.3.4
Input Stage Linearization
7.3.5
Rail-to-Rail Output
7.3.6
Low Input Bias Current
7.3.7
Slew Boost
7.3.8
EMI Rejection Ratio (EMIRR)
7.4
Device Functional Modes
8
Application and Implementation
8.1
Application Information
8.2
Typical Applications
8.2.1
Typical OPA207 Application
8.2.1.1
Design Requirements
8.2.1.2
Detailed Design Procedure
8.2.1.3
Application Curve
8.2.2
Precision Low-Side Current Sensing
8.2.3
Precision Buffer With Increased Output Current
9
Power Supply Recommendations
10
Layout
10.1
Layout Guidelines
10.2
Layout Example
11
Device and Documentation Support
11.1
Device Support
11.1.1
Development Support
11.1.1.1
Webench Filter Designer Tool
11.1.1.2
TINA-TI (Free Software Download)
11.1.1.3
TI Precision Designs
11.2
Documentation Support
11.2.1
Related Documentation
11.3
Receiving Notification of Documentation Updates
11.4
Support Resources
11.5
Trademarks
11.6
Electrostatic Discharge Caution
12
Mechanical, Packaging, and Orderable Information
Package Options
Mechanical Data (Package|Pins)
D|8
MSOI002K
DGK|8
MPDS028E
DBV|5
MPDS018T
Thermal pad, mechanical data (Package|Pins)
Orderable Information
sbos826d_oa
sbos826d_pm
6.2
ESD Ratings
VALUE
UNIT
V
(ESD)
Electrostatic discharge
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001
(1)
2000
V
Charged-device model (CDM), per JEDEC specification JESD22-C101
(2)
1000
(1)
JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(2)
JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.