Changes from * Revision (June 2017) to A Revision
- Added OPA180-Q1 and OPA4180-Q1 device temperature grades to Features list Go
- Changed OPA2180-Q1 device temperature grade from grade 1 to grade 2 in Features listGo
- Changed OPA2180-Q1 ambient operating temperature range from "–40°C to +105°C" to "–40°C to +125°C" in Features listGo
- Changed OPA180-Q1 and OPA4180-Q1 operating temperature from "–40°C to +105°C" to "–40°C to +125°C" in Description sectionGo
- Changed input offset voltage drift temperature range from TA = –40°C to 105°C to TA = –40°C to +125°C in Electrical Characteristics tableGo
- Changed power supply rejection ratio temperature range from TA = –40°C to 105°C to TA = –40°C to +125°C in Electrical Characteristics tableGo
- Changed OPA180-Q1 input bias current temperature range from TA = –40°C to 105°C to TA = –40°C to +125°C in Electrical Characteristics tableGo
- Changed OPA180-Q1 input offset current temperature range from TA = –40°C to 105°C to TA = –40°C to +125°C in Electrical Characteristics tableGo
- Changed common-mode rejection ratio temperature range from TA = –40°C to 105°C to TA = –40°C to +125°C in Electrical Characteristics tableGo
- Changed open-loop voltage gain temperature range from TA = –40°C to 105°C to TA = –40°C to +125°C in Electrical Characteristics tableGo
- Changed voltage output swing from rail temperature range from TA = –40°C to 105°C to TA = –40°C to +125°C in Electrical Characteristics tableGo
- Changed quiescent current temperature range from TA = –40°C to 105°C to TA = –40°C to +125°C in Electrical Characteristics tableGo
- Changed operating temperature from "–40°C to +105°C" to " –40°C to +125°C" in Feature Description sectionGo
- Updated Figure 34Go