over operating ambient temperature range (unless otherwise noted) (1)
|
MIN |
MAX |
UNIT |
Supply voltage, VS = (V+) – (V–) |
Supply voltage, VS = (V+) – (V–) |
0 |
7 |
V |
Signal input pins |
Common-mode voltage (2) (3) |
– 0.5 |
6.0 |
V |
Differential voltage (2) (3) |
|
±6.0 |
V |
Current (3) |
–10 |
10 |
mA |
Output short-circuit (4) |
Continuous |
Operating ambient temperature, TA |
–55 |
150 |
°C |
Junction temperature, TJ |
|
150 |
°C |
Storage temperature, Tstg |
–65 |
150 |
°C |
(1) Operation outside the Absolute
Maximum Rating may cause permanent device damage. Absolute Maximum Rating do
not imply functional operation of the device at these or any other conditions beyond those
listed under Recommended Operating Condition. If used outside the Recommended
Operating Condition but within the Absolute Maximum Rating, the device may not
be fully functional, and this may affect device reliability, functionality, performance, and
shorten the device lifetime.
(2) Input pins can swing beyond (V+) as long as they stay with in 6.0V. No diode structure from input pins to (V+).
(3) Input pins are diode-clamped to (V–). Input signals that 0.3V below
(V–) must be current-limited to 10mA or less.
(4) Short-circuit to ground, one amplifier per package.