PIN | I/O | DESCRIPTION | ||
---|---|---|---|---|
NAME | SOT-23 | SOIC | ||
ENABLE | 5 | 8 | — | Amplifier power down.
Low = disabled, high = normal operation (pin must be driven) |
IN+ | 3 | 3 | I | Noninverting input pin |
IN– | 4 | 2 | I | Inverting input pin |
NC | — | 1,5 | — | Do not connect. |
OUT | 1 | 6 | O | Output pin |
V+ | 6 | 7 | — | Positive power supply |
V– | 2 | 4 | — | Negative power supply |
PIN | I/O | DESCRIPTION | |
---|---|---|---|
NAME | NO. | ||
ENABLE A | 5 | — | Amplifier power down, channel A.
Low = disabled, high = normal operation (pin must be driven) |
ENABLE B | 6 | — | Amplifier power down, channel B.
Low = disabled, high = normal operation (pin must be driven) |
+IN A | 3 | I | Noninverting input pin, channel A |
+IN B | 7 | I | Noninverting input pin, channel B |
–IN A | 2 | I | Inverting input pin, channel A |
–IN B | 8 | I | Inverting input pin, channel B |
OUT A | 1 | O | Output pin, channel A |
OUT B | 9 | O | Output pin, channel B |
V+ | 10 | — | Positive power supply |
V– | 4 | — | Negative power supply |
PIN | I/O | DESCRIPTION | |
---|---|---|---|
NAME | NO. | ||
ENABLE A | 1 | — | Amplifier power down, channel A.
Low = disabled, high = normal operation (pin must be driven) |
ENABLE B | 2 | — | Amplifier power down, channel B.
Low = disabled, high = normal operation (pin must be driven) |
ENABLE C | 3 | — | Amplifier power down, channel C.
Low = disabled, high = normal operation (pin must be driven) |
+IN A | 5 | I | Noninverting input pin, channel A |
+IN B | 10 | I | Noninverting input pin, channel B |
+IN C | 12 | I | Noninverting input pin, channel C |
–IN A | 6 | I | Inverting input pin, channel A |
–IN B | 9 | I | Inverting input pin, channel B |
–IN C | 13 | I | Inverting input pin, channel C |
OUT A | 7 | O | Output, channel A |
OUT B | 8 | O | Output channel B |
OUT C | 14 | O | Output, channel C |
V+ | 4 | — | Positive power supply |