SCPS125H April 2006 – March 2022 PCA9536
PRODUCTION DATA
PARAMETER | TEST CONDITIONS | VCC | MIN | TYP(1) | MAX | UNIT | |
---|---|---|---|---|---|---|---|
VIK | Input diode clamp voltage | II = –18 mA | 2.3 V to 5.5 V | –1.2 | 0 | V | |
VPORR | Power-on reset voltage, VCC rising | VI = VCC or GND, IO = 0 | 1.2 | 1.6 | V | ||
VPORF | Power-on reset voltage, VCC falling | VI = VCC or GND, IO = 0 | 0.75 | 1 | V | ||
VOH | P-port high-level
output voltage(2) | IOH = –8 mA | 2.3 V | 1.8 | V | ||
3 V | 2.6 | ||||||
4.5 V | 4.1 | ||||||
4.75 V | 4.1 | ||||||
IOH = –10 mA | 2.3 V | 1.7 | |||||
3 V | 2.5 | ||||||
4.5 V | 4 | ||||||
4.75 V | 4 | ||||||
IOL | SDA | VOL = 0.4 V | 2.3 V to 5.5 V | 3 | 10 | mA | |
P-port(3) | VOL = 0.5 V | 2.3 V | 8 | 10 | |||
3 V | 8 | 14 | |||||
4.5 V | 8 | 17 | |||||
4.75 V | 8 | 32 | |||||
VOL = 0.7 V | 2.3 V | 10 | 13 | ||||
3 V | 10 | 19 | |||||
4.5 V | 10 | 24 | |||||
4.75 V | 10 | 44 | |||||
II | SCL, SDA | VI = VCC or GND | 2.3 V to 5.5 V | ±1 | μA | ||
IIH | P-port | VI = VCC | 2.3 V to 5.5 V | 1 | μA | ||
IIL | P-port | VI = GND | 2.3 V to 5.5 V | –100 | μA | ||
ICC | Operating mode | VI = VCC, IO = 0, I/O = inputs, fscl = 400 kHz | 5.5 V | 73 | 150 | μA | |
3.6 V | 9 | 50 | |||||
2.7 V | 7 | 30 | |||||
VI = VCC, IO = 0, I/O = inputs, fscl = 100 kHz | 5.5 V | 14 | 25 | ||||
3.6 V | 9 | 20 | |||||
2.7 V | 6 | 15 | |||||
Standby mode | VI = GND, IO = 0, I/O = inputs, fscl = 0 kHz | 5.5 V | 225 | 350 | |||
3.6 V | 175 | 250 | |||||
2.7 V | 125 | 200 | |||||
VI = VCC, IO = 0, I/O = inputs, fscl = 0 kHz | 5.5 V | 0.25 | 1.8 | ||||
3.6 V | 0.2 | 1.2 | |||||
2.7 V | 0.1 | 1 | |||||
ΔICC | Additional current in standby mode | One input at VCC – 0.6 V, Other inputs at VCC or GND | 2.3 V to 5.5 V | 0.35 | mA | ||
Every LED I/O at VI = 4.3 V, fscl = 0 kHz | 5.5 V | 0.4 | |||||
Ci | SCL | VI = VCC or GND | 2.3 V to 5.5 V | 4 | 5 | pF | |
Cio | SDA | VIO = VCC or GND | 2.3 V to 5.5 V | 5 | 6.5 | pF | |
P-port | 7.5 | 9.5 |