SBAS495D June 2010 – August 2021 PCM9211
PRODUCTION DATA
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
SFSST | SCSBIT1 | RSV | RSV | SESOUT3 | SESOUT2 | SESOUT1 | SESOUT0 |
R-N/A | R-N/A | R-N/A | R-N/A | R-N/A | R-N/A | R-N/A | R-N/A |
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
SFSST: Incoming Biphase Signal, Sampling Frequency Calculate Status | ||
0: | SFSOUT[3:0] Output is calculated | |
1: | In the process of calculating or unlocked | |
SCSBIT1: Detected Channel Status Bit1 Flag | ||
0: | CS Bit1 = 0 (Audio data) | |
1: | CS Bit1 = 1 (Non-audio data) | |
SFSOUT[3:0]: Incoming Biphase Signal, Actual Sampling Frequency | ||
0000: | Out of range | |
0001: | 8 kHz | |
0010: | 11.025 kHz | |
0011: | 12 kHz | |
0100: | 16 kHz | |
0101: | 22.05 kHz | |
0110: | 24 kHz | |
0111: | 32 kHz | |
1000: | 44.1 kHz | |
1001: | 48 kHz | |
1010: | 64 kHz | |
1011: | 88.2 kHz | |
1100: | 96 kHz | |
1101: | 128 kHz | |
1110: | 176.4 kHz | |
1111: | 192 kHz |
When SFSST becomes 1 (that is, in the process of calculating or unlocked), SFSOUT holds the previous data. SFSST and SFSOUT always output the status when these registers are read. The other registers do not have clear functions when these are read. To enable these registers, DIR must be powered on (register 40h/RXDIS = 0).