SLASEJ4C April 2017 – February 2023 PGA460
PRODUCTION DATA
Because the REGISTER READ command requires the controller to specify a register address in the PGA460 memory, an additional frame type is defined where the controller issues the sync and command fields followed by the memory register address as the only byte field in the controller frame and a controller checksum as the last field. Following the controller-to-peripheral transmission, the PGA460 device responds with a standard PGA460 Response Operation frame. #X286 shows this operation.
If a RESPONSE command arrives on the UART interface while another NO-RESPONSE command is also served or if the PGA460 device is busy performing functions, then the PGA460 device responds with a diagnostic field (see the GUID-4DE9AD14-E797-4362-85CB-40CC6DC34D3C.html#TITLE-SLASEC8X5623 section) having an error status of 0 which denotes that the device is busy serving functions. If the PGA460 is currently serving a RESPONSE command while another RESPONSE command arrives, then the PGA460 device ignores the new RESPONSE command until it is done serving the previous RESPONSE command.