SBOSA80 December 2021 REF20-Q1
PRODUCTION DATA
Most single-supply systems require an additional stable voltage in the middle of the analog-to-digital converter (ADC) input range to bias input bipolar signals. The VREF and VBIAS outputs of the REF20xx-Q1 are generated from the same band-gap voltage as shown in the Section 9.2. Hence, both outputs track each other over the full temperature range of –40°C to 125°C with an accuracy of 7 ppm/°C (maximum). The tracking error is calculated using the box method, as described by Equation 2:
where
The tracking accuracy is as shown in Figure 9-1.