SBVS020C September 2000 – February 2020 REF200
PRODUCTION DATA.
The design requirements are as follows:
The design goals and performance are summarized in Table 1. Figure 15 depicts the measured transfer function of the design.
VOUT | RTD | GOAL | CALCULATED | SIMULATED | MEASURED |
---|---|---|---|---|---|
VOUT maximum scale | 80.3 Ω | 0.1 V | 0.112 V | 0.117 V | 0.11 3 V |
VOUT minimum scale | 142.9 Ω | 4.9 V | 4.83 V | 4.82 V | 4.862 V |