SCBS842E September   2001  – February 2019 RI-TRP-DR2B

PRODUCTION DATA.  

  1. 1Device Overview
    1. 1.1 Features
    2. 1.2 Applications
    3. 1.3 Description
  2. 2Revision History
  3. 3Specifications
    1. 3.1 Absolute Maximum Ratings
    2. 3.2 ESD Ratings
    3. 3.3 Recommended Operating Conditions
    4. 3.4 Electrical Characteristics
    5. 3.5 Physical Characteristics
  4. 4Device and Documentation Support
    1. 4.1 Getting Started and Next Steps
    2. 4.2 Device Nomenclature
    3. 4.3 Documentation Support
    4. 4.4 Community Resources
    5. 4.5 Trademarks
    6. 4.6 Electrostatic Discharge Caution
    7. 4.7 Export Control Notice
    8. 4.8 Glossary
  5. 5Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
  • TRP|0
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Electrical Characteristics

over operating free-air temperature range (unless otherwise noted)
PARAMETER RI-TRP-DR2B UNIT
Functionality MPT
Memory 1360 bits
17 R/W pages
Operating Frequency 134.2 kHz
Modulation FSK (frequency shift keying), 134.2 kHz and 123.2 kHz
Transmission Principle HDX (half duplex)
Power Source Powered from the reader signal (batteryless)
Typical Read Range ≤100(1) cm
Typical Programming Range 30% of specified reading range
Typical Read Time 86 ms
Typical Programming Time 293 ms
Typical Programming Cycles 100000
Depends on RF regulation in country of use, the reader antenna configuration used, and the environmental conditions.