SCAS518F July   1995  – November 2024 SN54ACT04 , SN74ACT04

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Switching Characteristics
    7. 5.7 Operating Characteristics
  7. Parameter Measurement Information
    1. 6.1 15
  8. Detailed Description
    1. 7.1 Functional Block Diagram
    2. 7.2 Feature Description
    3. 7.3 Device Functional Modes
  9. Application Information Disclaimer
    1. 8.1 Power Supply Recommendations
    2. 8.2 Layout
      1. 8.2.1 Layout Guidelines
        1. 8.2.1.1 Layout Example
  10. Device and Documentation Support
    1. 9.1 Documentation Support
      1. 9.1.1 Related Links
    2. 9.2 Receiving Notification of Documentation Updates
    3. 9.3 Support Resources
    4. 9.4 Trademarks
    5. 9.5 Electrostatic Discharge Caution
    6. 9.6 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • J|14
  • FK|20
  • W|14
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Electrical Characteristics

over recommended operating free-air temperature range (unless otherwise noted)
PARAMETERTEST CONDITIONSVCCTA = 25°CSN54ACT04SN74ACT04UNIT
MINTYPMAXMINMAXMINMAX
VOHIOH = –50 µA4.5 V4.44.494.44.4V
5.5 V5.45.495.45.4
IOH = –24 mA4.5 V3.863.73.76
5.5 V4.864.74.76
IOH = –50 mA(1)5.5 V3.85
IOH = –75 mA(1)5.5 V3.85
VOLIOL = 50 µA4.5 V0.0010.10.10.1V
5.5 V0.0010.10.10.1
IOL = 24 mA4.5 V0.360.50.44
5.5 V0.360.50.44
IOL = 50 mA(1)5.5 V1.65
IOL = 75 mA(1)5.5 V1.65
IIVI = VCC or GND5.5 V±0.1±1±1µA
ICCVI = VCC or GND,IO = 05.5 V24020µA
∆ICC(2)One input at 3.4 V,
Other inputs at GND or VCC
5.5 V0.61.61.5mA
CiVI = VCC or GND5 V4.5pF
Not more than one output should be tested at a time, and the duration of the test should not exceed 2 ms.
This is the increase in supply current for each input that is at one of the specified TTL voltage levels, rather than 0 V or VCC.